This Pole Mount is designed to meet your site-specific inputs which are modules with dimensions of 70 inches by 48 inches and an array layout of 7 wide by 3 high.
This mount fits on 2 – 6in Pipe Sch 40 inch steel pole(s) with a spacing of 22.5 feet (not included).
The package includes a rail kit with all hardware necessary to attach and bond the solar modules to the rack. A chain hoist and lift bracket are needed for each pole (not included).
See 3D Model Here
MTSOLAR_H7G6J0HKE954
$10,682.26
Description
This Pole Mount is designed to meet your site-specific inputs which are modules with dimensions of 70 inches by 48 inches and an array layout of 7 wide by 3 high.
This mount fits on 2 – 6in Pipe Sch 40 inch steel pole(s) with a spacing of 22.5 feet (not included).
The package includes a rail kit with all hardware necessary to attach and bond the solar modules to the rack. A chain hoist and lift bracket are needed for each pole (not included).
See 3D Model Here
Additional information
Weight | 2004.1399999999999 lbs |
---|---|
Dimensions | 90 × 24 × 24 in |
SKU CODE | 2P-22.5-6TOP-XD-57-L-3HX7W-5HGL |
DUTY SIZE | XD |
POLE SIZE | 6IN, PIPE, SCH, 40 |
PRODUCT TYPE | BEAM |
NUMBER OF POLES | 2.00 |
POLE SPACING | 22.50 |
POLE HEIGHT | 9.05 |
WING SPAN | 57.00 |
MAX FOUNDATION DEPTH | 7.25 |
TILT ANGLE | 10.00 |
CANTILEVER | 474.00 |
GROUND CLEARANCE | 8.00 |
NO POLES | 2.00 |
MODULE AREA | 502.18 |
ARRAY WIDTH | 41.42 |
ARRAY HEIGHT | 12.13 |
RAIL LENGTH | 145.50 |
MODULE LENGTH | 70.00 |
PASSED OVERHANG CHECK | TRUE |
MODULE WIDTH GAP | 0.50 |
MODULE LENGTH GAP | 1.00 |
TOTAL FRAME LENGTH | 39.50 |
GROUND TO TOP | 10.09 |
PROJECTED PANEL HEIGHT | 2.08 |
PROJECT ID | MTSOLAR, H7G6J0HKE954 |
SITE ADDRESS | 3690, SILVARIO, CT, COTTONWOOD, CA, 96022, USA |
MODULE WIDTH | 48.00 |
NUMBER ROWS | 3.00 |
NUMBER COLUMNS | 7.00 |
RISK CATEGORY | I |
EXPOSURE CATEGORY | B |
FRAME DUTY OVERRIDE | AUTO |
POLE OVERRIDE | AUTO |
SOIL TYPE | SAND |
CUSTOMER FOUNDATION OVERRIDE | 36, ROUND |
FOUNDATION TYPE | ROUND |
FOUNDATION SIZE | 36.00 |
CHECK RAILS | FALSE |
WIND SPEED OVERRIDE | 130.00 |
SNOW LOAD OVERRIDE | 45.00 |
DIRECT SNOW LOAD | FALSE |
ADD ANGLE BRACE | FALSE |
TOTAL PRICE | 10682.26 |
TOTAL WEIGHT | 2004.14 |
TOTAL PALLETS | 2.00 |
https://skycivquotes.s3.amazonaws.com/76d68967-71df-4d80-9347-d81a62fd77e5.pdf |
|
ID | 6917.00 |
3D Solar link |